Software Problems - Lenovo System x3250 M5 Installation And Service Manual

Hide thumbs Also See for System x3250 M5:
Table of Contents

Advertisement

Table 29. ServerGuide problems and actions
Symptom
The ServerGuide Setup and
Installation CD will not start.
The ServeRAID Manager
program cannot view all
installed drives, or the
operating system cannot
be installed.
The operating-system
installation program
continuously loops.
The ServerGuide program will
not start the operating-system
CD.
The operating system cannot
be installed; the option is not
available.

Software problems

• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• If an action step is preceded by '(Trained technician only)', that step must be performed only by a Trained
technician.
• Go to the Lenovo support website at http://www.lenovo.com/support to check for technical information,
hints, tips, and new device drivers or to submit a request for information.
Table 30. Software problems and actions
Symptom
You suspect a software
problem.
Action
1. Make sure that the server supports the ServerGuide program and has a
startable (bootable) DVD drive.
2. If the startup (boot) sequence settings have been changed, make sure that the
DVD drive is first in the startup sequence.
3. If more than one DVD drive is installed, make sure that only one drive is set as
the primary drive. Start the CD from the primary drive.
1. Make sure that the hard disk drive is connected correctly.
2. Make sure that the SAS hard disk drive cables are securely connected.
Make more space available on the hard disk.
Make sure that the operating-system CD is supported by the ServerGuide
program. For a list of supported operating-system versions, go to
http://www.ibm.com/support/entry/portal/docdisplay?lndocid=SERV-GUIDE, click
the link for your ServerGuide version, and scroll down to the list of supported
Microsoft Windows operating systems.
Make sure that the server supports the operating system. If it does, either no logical
drive is defined (SCSI RAID servers), or the ServerGuide System Partition is not
present. Run the ServerGuide program and make sure that setup is complete.
Action
1. To determine whether the problem is caused by the software, make sure that:
• The server has the minimum memory that is needed to use the software. For
memory requirements, see the information that comes with the software.
If you have just installed an adapter or memory, the server might have a
memory-address conflict.
• The software is designed to operate on the server.
• Other software works on the server.
• The software works on another server.
2. If you received any error messages when using the software, see the information
that comes with the software for a description of the messages and suggested
solutions to the problem.
3. Contact the software vendor.
.
Chapter 4
Troubleshooting
139

Advertisement

Table of Contents
loading