Read the safety information in "Safety" on page v and "Installation guidelines" on page 31.
If you are replacing a server component in the server, you need to slide the server out from the rack
enclosure, turn off the server and peripheral devices, and disconnect the power cords and all external cables.
To replace the PCI riser-card assembly, complete the following steps.
Step 1.
Install the adapter in the PCI riser-card assembly (see "Replacing an adapter" on page 185 or
"Replacing an Lenovo ServeRAID SAS/SATA controller" on page 188).
Step 2.
Reconnect any adapter cables that you disconnected when you removed the PCI riser-card
assembly.
Step 3.
Carefully align the PCI riser-card assembly with the guides on the rear of the server and with the
PCI riser-card connector on the system board; then, place your thumbs on locations marked by the
blue tabs and press down on the PCI riser-card assembly. Make sure that the riser-card assembly
is fully seated in the connector on the system board.
Figure 92. PCI riser-card assembly installation
Step 4.
Reinstall the cover (see "Replacing the cover" on page 158).
What to do next
1. Install the server into the rack enclosure and push the server into the rack until it clicks into place.
2. Reconnect the power cords and any cables that you removed.
3. Turn on the peripheral devices and the server.
Removing the RAID adapter battery or flash power module holder
Use this information to replace the RAID adapter battery or flash power module holder in the server.
Note: RAID adapter battery or flash power module holder is only supported in the 2.5-inch models.