Figure 129. USB embedded hypervisor flash device installation
Step 3.
Reinstall the PCI riser-card assembly (see "Replacing the PCI riser-card assembly" on page 163).
Step 4.
Reinstall the cover (see "Replacing the cover" on page 158).
What to do next
1. Install the server into the rack enclosure and push the server into the rack until it clicks into place.
2. Reconnect the power cords and any cables that you removed.
3. Turn on the peripheral devices and the server.
Removing the front I/O assembly (USB cable and operator information panel)
Use this information to remove the front I/O assembly (USB cable and operator information panel) in the
server.
Read the safety information in "Safety" on page v and "Installation guidelines" on page 31.
If you are replacing a server component in the server, you need to slide the server out from the rack
enclosure, turn off the server and peripheral devices, and disconnect the power cords and all external cables.
To remove the front I/O assembly (USB cable and operator information panel), complete the following steps.
Step 1.
Remove the cover (see "Removing the cover" on page 157).
Step 2.
Disconnect the USB cable connector and the operator information panel cable connector from the
system board.
200