4. If problem re-occurs on the same DIMM connector, swap the other DIMMs on the same memory
channel across channels one at a time to a different memory channel or Processor. (check
service information for this product/Install guide for population requirements for sparing/paring
modes). If problem follows a moved DIMM to a different memory channel, replace that DIMM.
5. Check IBM Support website for an applicable service bulletin or firmware update that applies
to this memory error.
6. (Trained service technician only) If problem stays with the original DIMM connector, re-inspect
DIMM connector for foreign material and remove, if found. If connector is damaged, replace
system board.
7. (Trained service technician only) Remove affected Processor and inspect Processor socket pins
for damaged or mis-aligned pins. If damage is found, or this is an upgrade Processor, replace
system board. If there are multiple Processor's, swap Processor's to move affected Procesor to
another Processor socket and retry. If problem follows the affected Processor (or there is only
one Processor), replace the affected Processor.
8. (Trained service technician only) Replace the system board.
• S.68005 [S.68005] An error has been detected by the the IIO core logic on Bus %. The Global Fatal
Error Status register contains %. The Global Non-Fatal Error Status register contains %. Please
check error logs for the presence of additional downstream device error data.
Explanation: Critical IOH-PCI Error
Severity
Error
User Response
Complete the following steps:
1. Check log for a separate error for an associated PCIe device and service that error.
2. Check IBM Support website for an applicable service bulletin or firmware update for the system
or adapter that applies to this error.
3. (Trained service technician only) Replace the system board.
• W.11004 [W.11004] A processor within the system has failed the BIST.
Explanation: Processor Self Test Failure Detected
Severity
Warning
User Response
Complete the following steps:
1. If the Processor or firmware was just updated, check IBM Support website for an applicable
service bulletin or firmware update that applies to this Processor error.
2. (Trained service technician only) If there are multiple Processor's, swap Processor's to move
affected Processor to another Processor socket and retry. If problem follows the affected
Processor, or this is a single Processor system, replace the Processor. Inspect Processor
socket on each Processor removal and replace system board first if damaged or mis-aligned
pins are found.
3. (Trained service technician only) Replace the system board.