Removing A Raid Adapter Battery Or Flash Power Module - Lenovo x3550 M5 Installation And Service Manual

Hide thumbs Also See for x3550 M5:
Table of Contents

Advertisement

Baffle pin
Baffle pin hole
Figure 37. Air baffle installation
Step 5.
Reinstall the cover (see "Replacing the cover" on page 120).
Step 6.
Slide the server into the rack.
Step 7.
Reconnect the power cords and any cables that you removed.
Step 8.
Turn on the peripheral devices and the server.

Removing a RAID adapter battery or flash power module

Use this information to remove a remotely installed RAID adapter battery or flash power module.
To remove a RAID adapter battery or flash power module, complete the following steps:
Note: The 2.5-inch hard disk drive server model supports up to two RAID adapter batteries or flash
power modules, while the 3.5-inch hard disk drive server model supports only one RAID adapter battery
or flash power module.
Step 1.
Read the safety information that begins on "Safety" on page v and "Installation guidelines" on
page 116.
Step 2.
Turn off the server and peripheral devices and disconnect all power cords.
Step 3.
Remove the cover (see "Removing the cover" on page 119).
Step 4.
Disconnect the cable from the connector on the battery or power module.
Note: The cable routing is different between 2.5-inch and 3.5-inch hard disk drive server models.
Air baffle
Baffle pin
Baffle pin hole
Chapter 5
.
Removing and replacing components
123

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents