10. Remove the mirror 1 frame from the scanner
unit, passing the lever of mirror 1 frame rear
through the hole of the scanner unit rear
frame.
11. Remove the round terminals of the scanner
wire in the scanner unit left side from the
scanner wire spring.
12. Remove the scanner wires from the scanner
unit.

(2-2)Fitting the scanner wires

Caution
When fitting the wires, be sure to use those specified below.
Machine front: (P/N: 2FB1224), gray
Machine rear: (P/N: 2FB1225), black
Fitting requires the following tools
Frame securing tools: (P/N: 302FB68290/2FB68290)
Scanner wire stoppers: (P/N: 3596811)
Procedure
1. Move the mirror 2 frame as shown in the fig-
ure and insert two frame securing tools into
the positioning holes at the front and rear of
the machine center to fix the mirror 2 frame
in position.
2. Fit the frame securing tools using each two
screws.
Hole
Lever
Scanner wire springs
Frame securing tools
Mirror 1 frame
Figure 1-6-77
Round terminals
Figure 1-6-78
Mirror 2 frame
Figure 1-6-79
2FB/2FC-3
1-6-39