Maintenance
item No.
Setting: separate setting
U053
1. Select Separate setting at the screen for selecting an item.
2. Select the item to be adjusted. The selected item is displayed in reverse.
3. Change the value using the cursor up/down keys.
Display
MAIN MOTOR
TC MOTOR
FIX MOTOR
RESIST MOTOR
POLYGON MOTOR
FEED MOTOR
4. Press the start key. The value is set.
Setting: thick paper setting
1. Select Thick setting at the screen for selecting an item.
2. Select the item to be adjusted. The selected item is displayed in reverse.
3. Change the value using the cursor up/down keys.
Display
TC MOTOR
FIX MOTOR
RESIST MOTOR
FEED MOTOR
4. Press the start key. The value is set.
Setting: transfer setting
Modify setting when faulty transfer occurs after replacing a transfer unit or a transfer belt.
1. Select TC Setting (Uneven Image) at the screen for selecting an item.
2. When the faulty transfer occurs near leading edge or trailing edge of paper (sample 1), press the numer-
ical key of Band Lead/Trail to increase the setting value.
3. When the faulty transfer occurs periodically, (sample 2), press the numerical key of Band Cycle to
decrease the setting value.
4. Press the start key. The value is set.
Supplement
Firmware MAIN: After 2910BM-XXX.XX setting possibility.
Completion
Press the stop/clear key at the screen for selecting an item. The screen for selecting a maintenance item No.
is displayed.
Description
Description
Drive motor speed adjustment
Transfer motor speed adjustment
Fuser motor speed adjustment
Registration motor speed adjustment
Polygon motor speed adjustment
Feed motor speed adjustment
Description
Transfer motor speed adjustment
Fuser motor speed adjustment
Registration motor speed adjustment
Feed motor speed adjustment
70 mm
Sample 1
Setting
range
-100 to 100
-100 to 100
-100 to 100
-100 to 100
-100 to 100
-100 to 100
Setting
range
-100 to 100
-100 to 100
-100 to 100
-100 to 100
64 mm
64 mm
64 mm
Sample 2
2FB/2FC-3
Default
setting
0
3
-4
1 (80 cpm)
-1 (60 cpm)
0
1 (80 cpm)
-1 (60 cpm)
Default
setting
5 (80 cpm)
4 (60 cpm)
5
0
0
1-4-17