10. Remove two screws from the rear fuser
housing.
11. Pull out the fuser heater M, S and L from the
fuser unit rear with the rear fuser housing.
12. Check or replace the fuser heater M, S and
L, and refit the heaters to the fuser unit.
* When replacing the fuser heater M, S and L
individually, fit the heaters using the screws
directing the solder side of the heater rear
terminal on.
13. Refit the front fuser holder to the fuser unit
and connect the terminals of the fuser
heater M, S and L.
14. Refit the front fuser cover, upper fuser frame
and upper fuser cover to the fuser unit.
15. Refit the fuser unit.