(2-2) Fitting the scanner wires

NOTE
When fitting the wires, be sure to use those specified below.
Machine front: (P/N: 2C912360), gray
Machine rear: (P/N: 2C912350), black

Fitting requires the following tools

Two frame securing tools (P/N 302C968310)
Two scanner wire stoppers (P/N 35968110)
Procedure
1. Remove the screw and remove the scanner
wire drum gear.
2. Remove the stop ring and bush from the
front of the scanner wire drum shaft.
3. Remove the scanner wire drum shaft from
the scanner unit.
Screw
Scanner wire drum gear
Figure 1-5-38
Bush
Scanner unit
Figure 1-5-39
Scanner wire drum shaft
Stop ring
2K5
Bush