2FB/2FC-2.0

(4) Detaching and refitting the image formation fan filter

Follow the procedure below to replace the image formation filter.
Procedure
1. Remove the image formation fan cover
while pushing the lever.
2. Remove the image formation fan filter from
the image formation fan cover.
3. Replace the image formation fan filter and
attach the filter to the image formation fan
cover.
4. Refit the image formation fan cover.
1-6-98
Lever
Figure 1-6-190
Image formation
fan filter
Figure 1-6-191
Image formation
fan cover
Image formation
fan cover