2KL/2KK

(2-2) Fitting the scanner wires

NOTE
When fitting the wires, be sure to use those specified below.
Machine front: (P/N: 2C91236), gray
Machine rear: (P/N: 2C91235), black
Fitting requires the following tools
Two frame securing tools (P/N 302C968310)
Two scanner wire stoppers (P/N 3596811)
Procedure
1. Remove the rear cover.
2. Remove the screw and remove the scanner
wire drum gear from the rear side of the
machine.
3. Remove the stop ring and bush.
1-5-22
Right middle cover
Hook
Both
Figure 1-5-38
Bush
Figure 1-5-39
Screw
Screw
Right middle cover
Both
Hook
Screw
Stop ring