(3) Detaching and refitting the transfer roller

Follow the procedure below to replace the transfer roller.
Procedure
1. Remove the transfer unit (see page 1-6-61).
2. Remove the transfer belt (see page 1-6-63).
3. Remove the screw of the transfer unit rear
and then remove the terminal, spring and
pin.
* When refitting the spring, make sure that the
wider edge is facing toward the terminal.
4. Push up the front and rear transfer roller
bearing using the flat-blade screwdriver, and
then remove the roller from the transfer unit.
5. Remove the bearings from the both ends of
the transfer roller.
6. Replace the transfer roller and attach the
roller to the transfer unit.
7. Refit the transfer belt to the transfer unit.
8. Refit the transfer unit.
Pin
Spring
Terminal
Figure 1-6-122
Transfer roller
Bearing
Figure 1-6-123
2FB/2FC
Bearing
Transfer unit
1-6-65