Connector
Pin No.
YC5
12
Connected
13
to the PWBs
14
15
16
1
YC6
Connected
2
to the
3
engine PWB
and main
4
PWB
5
6
7
8
9
10
YC7
1
Connected
2
to the AC
3
power
4
source PWB
5
YC8
1
Connected
to the AC
2
power
3
source PWB
1
YC9
Connected
2
to the power
source fan
motor
YC10
1
Connector
2
3
4
5
6
YC11
1
Connected
2
to the hard
3
disk
4
Signal
I/O
S5V
O
S5V
O
S5V
O
S5V
O
S5V
O
RELAY
I
SOURCE
RELAY REM
I
ZEROCROSS
O
SLEEP
I
PS FAN H/L
I
CS HEATER
I
HEATER1
I
HEATER2
I
SUB HEATER
I
N.C
-
S5V
O
CS HEATER
O
HEATER1
O
HEATER2
O
SUB HEATER
O
AC LIVE IN
I
-
-
AC NEUTRAL
I
IN
PS FAN
O
SOURCE
PGND
-
5V
O
5V
O
SGND
-
SGND
-
24V
O
PGND
-
S12V
O
SGND
-
SGND
-
5V
O
Voltage
5 V DC
5 V DC power output for main PWB
5 V DC
5 V DC power output
5 V DC
5 V DC power output for cassette PWB
5 V DC
5 V DC power output for duplex PWB
5 V DC
5 V DC power output for deck PWB
24 V DC
24 V DC power output (via front cover switch/right
cover switch)
0/24 V DC
Relay control signal
0/5 V DC
Zero cross signal
(pulse)
0/5 V DC
Sleep control signal
0/5 V DC
Power source fan motor: Full speed/half speed
0/5 V DC
Drawer heater 1, 2 and 3: On/off
0/5 V DC
Fuser heater M: On/off
0/5 V DC
Fuser heater L: On/off
0/5 V DC
Fuser heater S: On/off
-
Not used
5 V DC
5 V DC power output
0/5 V DC
Drawer heater 1, 2 and 3: On/off
0/5 V DC
Fuser heater M: On/off
0/5 V DC
Fuser heater L: On/off
0/5 V DC
Fuser heater S: On/off
120 V AC
AC power input
220-240 V AC
-
Not used
120 V AC
AC power input
220-240 V AC
24 V DC
24 V DC power output
-
Power ground
5 V DC
5 V DC power output
5 V DC
5 V DC power output
-
Signal ground
-
Signal ground
24 V DC
24 V DC power output
-
Power ground
12 V DC
12 V DC power output
-
Signal ground
-
Signal ground
5 V DC
5 V DC power output
2FB/2FC
Description
2-3-7