2FB/2FC
1-6-8
Cleaning section
(1) Detaching and refitting the cleaning unit
Procedure
1. Open front cover and then remove the
toner container.
2. Remove two screws and pull out the image
formation unit.
3. Remove the connector of the image forma-
tion unit left.
4. Release two gray lock levers of the image
formation unit left.
5. Release two white lock levers of the image
formation unit upper.
6. Remove the cleaning unit from the image
formation unit.
1-6-66
White lock lever
Gray lock lever
Cleaning unit
White lock lever
Gray lock lever
Connector
Figure 1-6-124
Figure 1-6-125