Kyocera KM-6030 Service Manual page 147

Hide thumbs Also See for KM-6030:
Table of Contents

Advertisement

2FB/2FC
Maintenance
item No.
Checking/clearing the solenoid count value
U922
Description
Displays and clears the count value of solenoid.
Purpose
To check the period of replacement of solenoid. Also to clear the count value after replacement.
Method
Press the start key.
Display
FS SOL COUNT
DUP SB SOL COUNT
Clearing
1. Press the reset key.
2. Press the start key. The value is cleared. The screen for selecting a maintenance item No. is displayed.
Setting
1. Select the item to be changed.
2. Enter a seven-digit value using the numeric keys.
3. Press the start key. The value is set. The screen for selecting a maintenance item No. is displayed.
Completion
To exit this maintenance item without changing the count, press the stop/clear key.
The screen for selecting a maintenance No. item is displayed.
Checking/clearing the system error counts
U925
Description
Displays and clears the count value of system error.
Purpose
To check the system error status by types.
Also to clear the service call code counts after replacing consumable parts.
Method
Press the start key. The count for system error detection by type is displayed.
Clearing
1. Select the counts for all system error and press the reset key.
2. Press the start key. The count is cleared.
Completion
To exit this maintenance item without changing the count, press the stop/clear key.
The screen for selecting a maintenance No. item is displayed.
Clearing the all copy counts and machine life counts
U927
Description
Resets all of the counts back to zero.
Supplement
The total account counter and the machine life counter can be cleared only once if all count values are 1000
or less.
Method
1. Press the start key. The screen for executing is displayed.
2. Press EXECUTE on the touch panel. It is displayed in reverse.
3. Press the start key. All copy counts and machine life counts are cleared.
CANNOT EXECUTE is displayed if the count cannot be cleared.
Completion
To exit this maintenance item without changing the count, press the stop/clear key. The screen for selecting a
maintenance item No. is displayed.
Checking machine life counts
U928
Description
Displays the machine life counts.
Purpose
To check the machine life counts.
Method
Press the start key. The current machine life counts is displayed.
Completion
Press the stop/clear key. The screen for selecting a maintenance item No. is displayed.
1-4-72
Description
Description
Feedshift solenoid (FSSOL)
Duplex switchback solenoid (DUPSBSOL)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Km-8030

Table of Contents