Kyocera KM-6030 Service Manual page 194

Hide thumbs Also See for KM-6030:
Table of Contents

Advertisement

Code
C2300
Fuser motor error
• LOCK signal remains high for 1 s, 1 s
after the fuser motor has turned on.
C2550
Transfer motor error
• LOCK signal remains high for 1 s, 1 s
after the transfer motor has turned on.
C2640
Side feeder drive motor error
C3100
Scanner carriage problem
• The home position is not correct when
the power is turned on or at the start of
copying using the MP tray.
Contents
Causes
Check procedures/corrective measures
Poor contact in the
Check the connection of connector YC2 and
fuser motor con-
YC4 on the duplex PWB. Reinsert the con-
nector terminals.
nector. Also check for continuity within the
connector cable. If none, remedy or replace
the cable.
Defective fuser
Replace the fuser motor.
motor rotation con-
trol circuit.
Defective drive
Check if the rollers and gears rotate smoothly.
transmission sys-
If not, grease the bushings and gears. Check
tem.
for broken gears and replace if any.
Defective duplex
Replace the duplex PWB or the engine
PWB or engine
PWB.
PWB.
Poor contact in the
Check the connection of connector YC2 and
transfer motor con-
YC3 on the cassette PWB and YC4 on the
nector terminals.
engine PWB. Reinsert the connector. Also
check for continuity within the connector
cable. If none, remedy or replace the cable.
Defective transfer
Replace the transfer motor.
motor rotation con-
trol circuit.
Defective drive
Check if the rollers and gears rotate
transmission sys-
smoothly. If not, grease the bushings and
tem.
gears. Check for broken gears and replace if
any.
Defective cassette
Replace the cassette PWB or the engine
PWB or engine
PWB.
PWB.
Overloaded side
Verify that the side feeder motor or the paper
feeder drive motor
feeding mechanism is not interrupted by any
objects.
Defective side
Replace the side feeder drive motor.
feeder drive motor.
Defective side
Replace the side feeder main PWB.
feeder main PWB.
Defective scanner
Replace the scanner PWB and check for
PWB.
correct operation.
Defective scanner
Replace the scanner home position switch.
home position
switch.
Defective scanner
Replace the scanner motor.
motor.
Poor contact in the
Check the connection of connector YC2,
connector termi-
YC5 and YC10 on the scanner PWB and the
nals.
continuity across the connector terminals.
Repair or replace if necessary.
Defective mirror
Check if the mirror flames and exposure
flame, exposure
lamp are on the rail. And check the scanner
lamp or scanner
wire winds correctly.
wire.
Remarks
2FB/2FC-4
1-5-33

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Km-8030

Table of Contents