C5600
Drum surface potential problem 1
• Grid voltage at 4.5 V could not deter-
mine the potential.
• Potential adjustment in 30 times could
not raise the potential sensor value to
the predetermined.
C5610
Drum surface potential problem 2
• Grid voltage at 0.3 V could not deter-
mine the potential.
• Potential adjustment in 30 times could
not lower the potential sensor value to
the predetermined.
C6000
Fuser heater lamp break
• The fuser temperature does not
increase for 40 s after the fuser heat-
ers have been turned on for warming
up.
• The fuser temperature remains below
°
°
50
C/122
F for 10 s continuously
after the fuser heaters have been
turned on during stabilization.
C6020
Fuser thermistor high-temperature
detection error
• The fuser temperature exceeds 235
°
°
C/455
F for 10 s.
• The fuser high-temperature signal is
detected for continous 500 ms.
Contents
Causes
Check procedures/corrective measures
Deteriorated main
Check the main charger wire and replace it if
charger.
necessary (see page 1-6-33).
Grid or main
Clean the grid or main charger shield if nec-
charger shield is
essary.
dirty.
Defective drum
Replace the drum surface potential sensor.
surface potential
sensor.
Defective high volt-
Replace the high voltage PWB and check
age PWB.
for correct operation.
Defective engine
Replace the engine PWB and check for cor-
PWB.
rect operation.
Defective drum
Replace the drum surface potential sensor.
surface potential
sensor.
Defective high volt-
Replace the high voltage PWB and check
age PWB.
for correct operation.
Defective drum.
Replace the drum (see page 1-6-56).
Defective engine
Replace the engine PWB.
PWB.
Installation defec-
Check the mounting state of the fuser ther-
tiveness on fuser
mistor M and S. If any problem is found,
thermistor M and S.
repair it.
Defective fuser
Replace the fuser thermostat (see page 1-6-
thermostat.
75).
Installation defec-
Check the mounting state of the fuser ther-
tiveness on fuser
mistor L, M and S. If any problem is found,
heater L, M or S.
repair it.
Broken fuser
Check for continuity. If none, replace the
heater L, M and S
fuser heater L, M and S (see page 1-6-76).
wire.
Defective engine
Replace the engine PWB.
PWB.
Defective AC
Replace the AC power source PWB.
power source
PWB.
Installation defec-
Check the mounting state of the fuser ther-
tiveness on fuser
mistor M and S. If any problem is found,
thermistor M and S.
repair it.
Defective fuser
Replace the fuser thermistor M and S (see
thermistor M and
page 1-6-75).
S.
Defective engine
Replace the engine PWB.
PWB.
Remarks