Maintenance
item No.
Setting the time out
U506
Description
Sets the communication timeout time for connection to a computer.
Purpose
To change the preset value if a communication error occurs after connection to a computer continues for a
long time. By delaying the error detection timing, the error may be cleared. If the error is not cleared after the
preset value is changed, however, return the preset value to the initial value.
Method
Press the start key. The current setting is displayed.
Setting
1. Change the value using the cursor up/down keys.
Description
Timeout time
The setting can be changed by 10 s per step.
2. Press the start key. The setting is set, and the screen for selecting a maintenance item No. is displayed.
Completion
To exit this maintenance item without changing the current setting, press the stop/clear key.
The screen for selecting a maintenance item No. is displayed.
Setting the LDAP
U508
Description
Enables or disables an LDAP server.
Purpose
To change the setting to ON when use of an LDAP server is requested.
Method
Press the start key. The screen for selecting an item is displayed.
Setting
1. Select ON or OFF. The selected item is displayed in reverse.
Display
ON
OFF
Initial setting: OFF
2. Press the start key. The setting is set, and the screen for selecting a maintenance item No. is displayed.
Completion
To exit this maintenance item without changing the current setting, press the stop/clear key.
The screen for selecting a maintenance item No. is displayed.
Description
Setting range
10 to 120 (s)
Description
LDAP server is enabled.
LDAP server is disabled.
Default setting
10