6. Remove seven springs from the separation
claws and then pull out the separation claws
shaft from the eject guide.
7. Replace the separation claws and attach the
claws to the eject guide.
8. Refit the eject guide.

(10) Detaching and refitting the fuser eject upper roller

Follow the procedure below to replace the fuser eject upper roller.
Procedure
1. Remove the eject guide from the eject sec-
tion (see page 1-6-80).
2. Remove the fuser eject upper roller from the
eject section.
3. Remove the two bearings from the fuser
eject upper roller.
4. Replace the fuser eject upper roller and
attach the roller to the eject section.
5. Refit the eject guide.
Springs
Eject guide
Separation
claws shaft
Figure 1-6-160
Eject section
Bearing
Figure 1-6-160-1
2FB/2FC-2.0
Spring
Separation
claw
Bearing
Fuser eject upper roller
1-6-81