Kyocera KM-6030 Service Manual page 428

Hide thumbs Also See for KM-6030:
Table of Contents

Advertisement

2FB/2FC
Connector
Pin No.
YC1
1
Connected
2
to the DC
3
power
4
source PWB
YC2
A1
Connected
A2
to the
A3
engine PWB
A4
A5
A6
A7
A8
A9
A10
A11
B1
B2
B3
B4
B5
B6
B7
B8
B9
B10
B11
1
YC4
Connected
2
to the fuser
motor
3
4
5
6
7
8
9
2-3-42
Signal
I/O
24V
I
PGND
-
SGND
-
5V
I
EJECT SW
O
FEED A SW
O
REG SW
O
N.C
-
DUP PAUSE
I
DUP SEL(O)
I
DUP RDY(I)
O
DUP SCLK(O)
I
DUP SDO
I
DUP SDI
O
SGND
-
FUSER MOT
I
REM
FUSER MOT
O
ALM
FEED MOT
I
MODE
FEED MOT
I
HLD
FEED MOT
I
REM
FEED MOT
I
CLK
REG MOT
I
MODE
REG MOT HLD
I
REG MOT REM
I
REG MOT CLK
I
SGND
-
FUSER MOT
O
CLK
FUSER MOT
I
ALM
FUSER MOT
O
REM
5V
O
SGND
-
PGND
-
PGND
-
R24V
O
R24V
O
Voltage
24 V DC
24 V DC power input
-
Power ground
-
Signal ground
5 V DC
5 V DC power input
0/5 V DC
Exit switch: On/off
0/5 V DC
Feed switch 1: On/off
0/5 V DC
Registration switch: On/off
-
Not used
0/5 V DC
Duplex PWB PAUSE signal
0/5 V DC
Duplex PWB SEL signal
0/5 V DC
Duplex PWB ready signal
0/5 V DC
Duplex PWB clock signal
(pulse)
0/5 V DC
Duplex PWB serial communication signal
(pulse)
0/5 V DC
Duplex PWB serial communication signal
(pulse)
-
Signal ground
0/24 V DC
Fuser motor: On/off
0/5 V DC
Fuser motor alarm signal
0/5 V DC
Feed motor mode signal
0/5 V DC
Feed motor hold signal
0/5 V DC
Feed motor: On/off
0/5 V DC
Feed motor clock signal
(pulse)
0/5 V DC
Registration motor mode signal
0/5 V DC
Registration motor hold signal
0/5 V DC
Registration motor: On/off
0/5 V DC
Registration motor clock signal
(pulse)
-
Signal ground
0/5 V DC
Fuser motor clock signal
(pulse)
0/5 V DC
Fuser motor alarm signal
0/24 V DC
Fuser motor: On/off
5 V DC
5 V DC power output
-
Signal ground
-
Power ground
-
Power ground
24 V DC
24 V DC power output
24 V DC
24 V DC power output
Description

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Km-8030

Table of Contents