Code
C8330
Document finisher* centerfold blade
problem
• During initialization, the centerfold
blade is not detected in the home posi-
tion within a specified period of time.
C9040
DP lift motor going up error
• The pulse count raised to 10000 at lift-
ing, however, the DP lift upper limit
switch could not be turned on. After
one time retry, the DP lift upper limit
switch could not be turned on.me.
C9050
DP lift motor going down error
• The pulse count raised to 10000 at lift-
ing, however, the DP lift lower limit
switch could not be turned on. After
one time retry, the DP lift lower limit
switch could not be turned on.me.
1-5-45-1
1-5-46
Contents
Causes
Check procedures/corrective measures
Loose connection
Reinsert the connector. Also check for conti-
of the centerfold
nuity within the connector cable. If none,
blade motor con-
remedy or replace the cable.
nector.
Malfunction of the
Replace the centerfold blade motor and
centerfold blade
check for correct operation.
motor.
Malfunction of the
Replace the centerfold blade home position
centerfold blade
sensor and check for correct operation.
home position sen-
sor.
Loose connection
Reinsert the connector. Also check for conti-
of the centerfold
nuity within the connector cable. If none,
blade home posi-
remedy or replace the cable.
tion sensor con-
nector.
Defective center-
Replace the centerfold unit main PWB and
fold unit main
check for correct operation.
PWB.
Loose connection
Reinsert the connector. Also check for conti-
of the DP lift motor
nuity within the connector cable. If none,
connector.
remedy or replace the cable.
Malfunction of the
Replace the DP lift motor and check for cor-
DP lift motor.
rect operation.
Malfunction of the
Replace the DP lift upper limit switch and
DP lift upper limit
check for correct operation.
switch.
Loose connection
Reinsert the connector. Also check for conti-
of the DP lift upper
nuity within the connector cable. If none,
limit switch con-
remedy or replace the cable.
nector.
Defective DP main
Replace the DP main PWB and check for
PWB.
correct operation.
Loose connection
Reinsert the connector. Also check for conti-
of the DP lift motor
nuity within the connector cable. If none,
connector.
remedy or replace the cable.
Malfunction of the
Replace the DP lift motor and check for cor-
DP lift motor.
rect operation.
Malfunction of the
Replace the DP lift lower limit switch and
DP lift lower limit
check for correct operation.
switch.
Loose connection
Reinsert the connector. Also check for conti-
of the DP lift lower
nuity within the connector cable. If none,
limit switch con-
remedy or replace the cable.
nector.
Defective DP main
Replace the DP main PWB and check for
PWB.
correct operation.