Adjusting the machine levelness.
1. Verify levelness at the four coners of the contact glass using a level gauge, and adjust the level
bolts at the bottom of the machine to optimize levelness.
Connecting the power cord.
1. Connect the power cord to the inlet on lower
left of the machine. (230 V specifications
only.)
2. Connect the power plug to the wall outlet.
Initial setting for the developing unit.
1. Turn on the power switch.
2. Enter 10871087 using the numeric keys to enter the maintenance mode.
3. Enter 130 using the numeric keys and press the start key.
4. Press the start key. Installation of the toner is started. (Approximately 5 minutes)
Display
DLP SENS: Presence of toner inside developing unit (1: No/0: Yes)
TIME(SEC): When it becomes 3 minutes before an installation end, it will count up from 0 and will become an instal-
lation end by 180.
RESULT: Result of the installation (0: During installation/1: Installation is successful/2: Installation is failed)
If the installation is failed, enter 001 using the numeric keys and press the start key to exit the maintenance mode.
When [Reinstall the toner container.] is displayed, pull out the container and tap and shake the container to agitate
the toner enough and re-install the container in the machine.
When [Add toner.] is displayed, replace the toner container.
5. After driving stops, press the stop/clear key.
6. Enter 001 using the numeric keys and press the start key. The machine exits the maintenance mode.
Make test copies.
1. Load paper in the cassette.
* When fixing the paper width guides position
of cassette 3 or 4, use M3 x 8 screws sup-
plied with the machine.
2. Make test copies.
1-3-10
Power cord
Figure 1-3-16
M3 x 8
screws
Figure 1-3-17
M3 x 8
screws
Paper width guides