M5040, M6040, M7040, WSM
Air Conditioner Ducts and Covers
1. Remove the duct 1 (1).
2. Remove the DT shift lever grip (2).
3. Remove the inner cover (L.H.) (3).
4. Remove the duct 2 (4).
5. Remove the seat under cover 1 (5).
6. Remove the seat under cover 2 (8).
7. Remove the duct 3 mounting screw (7) for removing duct 3 (6).
(1) Duct 1
(2) DT Shift Lever Grip
(3) Inner Cover (L.H.)
(4) Duct 2
Wiring Harness
1. Disconnect the 2P connector (1) for pressure switch.
2. Disconnect the 2P connector (2) for blower motor.
3. Disconnect the 4P connector (8) for blower resistor.
4. Disconnect the 5P connector (7) for recirculation/fresh air
selection motor.
5. Disconnect the 7P connector (3) for air mix control motor.
6. Disconnect the 1P connector (5) for thermistor.
7. Disconnect the 5P connector (6) for thermostat.
8. Disconnect the relay box (4) from cabin.
(1) 2P Connector (Pressure Switch)
(2) 2P Connector (Blower Motor)
(3) 7P Connector (Air Mix Control Motor)
(4) Relay Box
(5) 1P Connector (Thermistor)
10-S42
(5) Seat Under Cover 1
(6) Duct 3
(7) Screw
(8) Seat Under Cover 2
W1031865
(6) 5P Connector (Thermostat)
(7) 5P Connector (Recirculation/Fresh
Air Selection Motor)
(8) 4P Connector (Blower Resistor)