Kubota M5040 Workshop Manual page 533

Table of Contents

Advertisement

M5040, M6040, M7040, WSM
Connector Voltage
1. Disconnect the 16P connector (2) from control panel switch.
2. Turn the main switch to "ON" position.
3. Measure the voltage with a voltmeter across the terminal o and
terminal n.
4. If the voltage differs from the battery voltage, the wiring harness,
A/C relay or fuse is faulty.
Terminal n –
Voltage
Terminal o
(1) Control Panel
(2) 16P Connector (Switch Side)
A/C Switch Checking
1. Measure the voltage with a voltmeter across the terminal k and
chassis.
2. Turn the main switch to "ON" position.
3. Turn the blower switch to "ON" position.
4. Press the air conditioner switch to set it to "OFF" position
(indicator : OFF), and then measure a voltage using a circuit
tester.
5. Press the air conditioner switch to set it at "ON" position
(indicator : ON), and then measure a voltage using a circuit
tester.
6. If a measured voltage does not comply with the values in the
table below, the control panel, wiring harness or fuse is faulty.
Terminal k –
Voltage
Chassis
(1) 16P Connector (Switch Side)
Mode Control Dial Checking
1. Disconnect the 16P connector from control panel switch.
2. Check the continuity through the switch with an ohmmeter.
3. If the continuity specified below is not indicated, the switch is
faulty.
Terminal
Position
FRONT
Mode switch
FULL
DEF
(1) 16P Connector (Switch Side)
10-S25
Approx. battery voltage
(3) 16P Connector (Wire Harness Side)
A/C switch at
Approx. battery voltage
ON
A/C switch at
Approx. 1 V
OFF
(2) 16P Connector (Wire Harness Side)
e
g
i
KiSC issued 06, 2008 A
CABIN
W1020794
W1020998
l
W1042432

Hide quick links: