M5040, M6040, M7040, WSM
When Clutch Pedal is Depressed (with Shuttle Lever at Reverse or Forward Position)
With the shuttle lever at R or F position, when the clutch pedal is depressed, the inching valve (4) is moved to the
right. And connect the passage 1 (f) to T2 port. As the proportionally reducing valve (1) is moved to the right by
pressure difference, R port (or F port) and T2 port are connected.
The oil in the shuttle clutch returns into the transmission case via R port (of F port) through the proportionally
reducing valve (1) and T2 port. This cause the shuttle clutch to be set to off.
As a result, even when the proportionally reducing valve (1) does not move, the oil passage from R port (or F side)
to T2 port is secured.
3-M12
TRANSMISSION
(1) Proportionally Reducing
Valve
(2) Shuttle Valve
(3) Shuttle Shift Spool
(Forward, Reverse)
(4) Inching Valve
(5) Modulating Valve
(6) Accumulate Valve
(7) Shuttle Lever
(8) Clutch Pedal
A : Check Port (Modulation)
B : Check Port (Reverse)
C : Check Port (Forward)
P : P Port (Pump)
T1 to T3 :To Transmission Case
(a) Connect to Shuttle Lever
(b) Connect to Clutch Pedal
(c) Neutral
(d) Forward
(e) Reverse
(f) Passage f
W1019696