(2) Checking Fuse
Directions for Storage
1. When shutting down the tractor for long periods of time, remove
the battery from the tractor, store the battery in a well ventilated
placed where it is not exposed to direct sunlight.
2. Since the battery self-discharges by approx. 0.5 % per day even
in storage, it must be once every two months in cold season.
3. When storaging the battery mounted on the tractor, disconnect
the ground cable from the battery's negative terminal post.
(Reference)
• Self-discharge Rate
Temperature
30 °C (86 °F)
20 °C (68 °F)
10 °C (50 °F)
Fuse (ROPS Model)
1. When inspect the circuit line, check the related fuses.
2. If any of the fuse is blown, replace with a new one of the same
capacity.
IMPORTANT
• If a fuse is blown, check the cause and be sure to replace it
with a new one of the same capacity.
Protected Circuit
Fuse I.D.
Capacity (A)
a
15
b
15
c
5
d
5
e
10
f
15
g
5
h
15
i
15
j
5
k
40
l
30
m
50
(1) Fuse Case
(2) Spare Fuse
9-S9
ELECTRICAL SYSTEM
Self-discharge rate
Approx. 1.0 % per day
Approx. 0.5 % per day
Approx. 0.25 % per day
W1017453
Protected circuit
Work light R
Work light L
Alternator, Engine glow plug
Meter panel, OPC
Turn signal
Auxiliary power
Meter (Back up)
Head light, Tail lamp
Flasher (Hazard)
Starter relay
Key switch, Head light, Hazard
Fuel cut solenoid, Work light
Charge, Glow plug
(3) Fuse Puller
W1015983
KiSC issued 06, 2008 A