M5040, M6040, M7040, WSM
Main Switch at ON Position
1. Turn the main switch to ON position.
2. Measure the resistance with an ohmmeter across the terminal 3
and the terminal 6.
3. If 0 ohm is not indicated, the 3 – 6 contacts of the main switch are
faulty.
Terminal 3 –
Resistance
Terminal 6
(1) Main Switch Connector
Main Switch at START Position
1. Turn and hold the main switch at the START position.
2. Measure the resistances with an ohmmeter across the terminal 5
and across terminal 3 and the terminal 6.
3. If 0 ohm is not indicated, these contacts of the main switch are
faulty.
Terminal 3 –
Terminal 5
Resistance
Terminal 3 –
Terminal 6
(1) Main Switch Connector
Main Switch at PREHEAT Position
1. Turn and hold the main switch key at the PREHEAT position.
2. Measure the resistances with an ohmmeter across the terminal 3
and terminal 2, and the terminal 3 and the terminal 6.
3. If 0 ohm is not indicated, these contacts of the main switch are
faulty.
Terminal 3 –
Terminal 2
Resistance
Terminal 3 –
Terminal 6
(1) Main Switch Connector
Main Switch at ACC Position
1. Turn the main switch key at the ACC position.
2. Measure the resistances with an ohmmeter across the terminal 3
and the terminal 1.
3. If 0 ohm is not indicated, these contacts of the main switch are
faulty.
Terminal 3 –
Resistance
Terminal 1
(1) Main Switch Connector
9-S14
ELECTRICAL SYSTEM
0 Ω
W1018982
0 Ω
0 Ω
W1019166
0 Ω
0 Ω
W1018647
0 Ω
W1018807
KiSC issued 06, 2008 A