Firmware History for B070/B071

NCS (NIB) FIRMWARE:

PART NUMBER
B0705735
A
B
B0705755
A
B

NCS (NIB) FIRMWARE HISTORY:

1. SC672 (controller start-up error).
2. NetWare printing error: Machine will not accept print jobs after a certain amount have
been sent via NetWare.
3. Words missing (French/Spanish): Some words not displayed in French (missing from
wording lists).
4. Slow printing speed with Standard TCP/IP port.
IMPORTANT: To ensure the above symptoms do not occur, it is also necessary to update to
the following firmware versions or later:
BIOS: B0705742D: K02EL00O
SYSTEM: B0705734B: V.1.04.4
LCDC: B0705371B (NA): V.2.07
1. Supports 0-counter change
2. Supports SMTP Authentication
1. Not possible to access the NIB from SmartNetMonitor (IPX environments only).
2. Not possible to access the network when an NVRAM clear is performed with the
IEEE1394 board installed.
3. The NIB is not able to limit access from the WebImageMonitor document server or
DeskTopBinder V2 Professional in accordance with the Access Control ranges specified in
WebImageMonitor (only when these settings have been specified).
4. Modified for use with Copy Connector Kit.
1. Modified for use with the MLB option (File Format Converter).
2. Hop count was mistakenly set at 4, making it impossible to obtain an auto IP address
when there are four or more routers between the unit and DHCP server (Hop count
corrected to 64).
CÓPIA NÃO CONTROLADA
VERSION
CHECK SUM
V4.01
V4.02
0CDB
V4.03
V4.11
AAE6
V4.13.3
V4.15
Symptom Corrected
CÓPIA NÃO CONTROLADA
PRODUCTION
-
1st Mass Prod.
February '03 Prod
20B5
March '03 Prod
April '03 Prod
6E90
May '03 Prod
301D
June '03 Prod
Version
B
B0705755
A
B
Page 9 of 12

Advertisement

Table of Contents
loading

This manual is also suitable for:

B071

Table of Contents