7. Mechanical adjustment

7.
Mechanical adjustment
7.1

Adjusting the paper reference position

NOTE
• Make this adjustment after any of the following procedures has been performed.
When the PH unit has been replaced.
When the image on the print is offset in the sub scan direction.
When a faint image occurs on the leading edge of the image.
7.1.1

Centering

A. Control panel
1. Call the Service Mode to the screen.
See P.228 of the main body service manual.
2. Select [MachineAdjustment] → [Printer Area] → [Centering] → [Tray 3].
3. Press the Menu/Select key.
4. Select [Print] and press the Menu/Select key to let the machine produce a test print.
24
A
4348fs3509c0
[1]
[2]
A093F3C506DA
Field Service Ver. 1.0 Oct. 2007
5. Measure the width of printed refer-
ence line A.
Specification: 3.0 mm
6. If the measured width A falls outside
the specified range, enter the correc-
tion value using the
7. Produce another test print and check
to see if width A falls within the spec-
ified range.
NOTE
• If the use of the
not allow the measurement to fall
within the specified range, perform
the following steps.
8. Press the drawer release button [1]
and then slide out the drawer [2]
from the paper feed cabinet.
±
1.0 mm
or
keys.
or
keys does

Advertisement