11. Other
11.3.26

Right door assy

1. Remove the lower rear cover/1 and the lower rear cover/2.
See P.101
2. Remove the manual bypass tray unit.
See P.111
3. Remove the high voltage unit.
See P.133
4. Slide out the paper feed tray 1.
5. Remove the right front cover/2.
See P.95
[2]
[3]
[1]
[1]
[2]
120
[2]
A02EF2C363DA
[2]
[1]
A02EF2C111DA
[1]
[1]
[2]
A02EF2C355DA
Field Service Ver. 1.0 Oct. 2007
6. Remove the harness from the edge
cover [1].
7. Remove four screws [2], and remove
the metal plate [3].
8. Remove two screws [1], and remove
the rear handle cover [2].
9. Remove eight screws [1], and
remove two reinforcement plates [2]
of the right door.