10. Firmware upgrade
4. Click [ON], and click [END].
When using the control panel, select [Enable] and press the Menu/Select key.
NOTE
• Settings such as server setting, etc. will be available by selecting "ON" on this set-
ting.
• When the following setting is set to "ON", "ON" cannot be selected on this setting.
[Admin. Settings] → [Security Settings] → [EnhancedSecurity]
B. Protocol setting
• It performs the setting concerning the protocol (ftp or http) for connecting to the
Internet ISW.
• When connecting to the program server using a proxy server, perform the setting
for a proxy server.
Step
Connecting by http
0
Select [Internet ISW] which is available from [Service Mode].
Data Input Setting
• Click [HTTP Setting], and select [ON].
1
Data acquisition setting (Control panel)
• Select [HTTP Settings] → [DataRetrievalSet]
→ [Enable].
Connect Proxy
2
• For connecting via proxy server, select [ON].
Proxy Server
• For connecting via proxy server, set the proxy server address and the port number.
3
1. Select the [Server Address], and set the proxy server address by IP addressing scheme or
FQDN scheme.
2. Select [Port Number], and set the port number for the proxy server from 1 through 65535.
Proxy Authentication
• Set the login name and the password which
may be necessary for authentication when
accessing to the proxy server.
1. When Authentication is necessary for
accessing to the proxy server, select
[Authentication], and select [ON].
When using the control panel, select [Auth.
Settings], and select [ON].
2. When using the jig software, select [Log-in
Name] and enter the login name with the
4
keyboard on the screen.
When using the control panel, enter the
auth. login name with the operation keys.
3. When using the jig software, select [Pass-
word] and enter the password with the key-
board on the screen.
When using the control panel, enter the
auth. password with the operation keys.
80
Field Service Ver. 1.0 Oct. 2007
Connecting by ftp
Data Input Setting
• Click [FTP Setting], and select [ON].
Data acquisition setting (Control panel)
• Select [FTP Settings] → [DataRetrievalSet]
→ [Enable].
Connection Setting
• Perform the setting for accessing FTP
server.
1. Select [Port Number], and set the port num-
ber for FTP server from 1 through 65535.
2. Select [Connection Time Out], and set the
time for the connection time out from 1
through 60.
When using the control panel, select [Time-
out], and set the time for the connection time
out from 1 through 60.
3. When connecting in PASV mode, select
[PASV Mode], and select [ON].
When using the control panel, select [PASV
Mode], and select [Enable].
*PASV Mode:
This mode is for transferring the file with
FTP under the condition where communica-
tion is restricted such as inside the firewall.
Since with PASV mode, the client with
restriction sets the port number, data trans-
mission port can be secured to enable the
file transmission.