11. Other
[1]
[2]
[1]
9. Reinstall the Image transfer belt unit.
10. Reinstall the front cover.
11. Make skew adjustment of the PH unit.
See P.389
NOTE
• When replacing the PH unit, make sure to conduct PH unit skew adjustment.
110
[1]
A02EF2C080DA
A02EF2C081DA
Field Service Ver. 1.0 Oct. 2007
5. Reinstall the gear [1].
NOTE
• Make sure that the gear claw is fit
in.
6. Connect the connector and the flat
cable.
NOTE
• Make sure the harness is installed
along with the harness guide.
7. Follow the same procedures to
install all the PH units.
8. Install the imaging unit guide rails [1].
NOTE
• Make sure that the two claws [2] at
rear end of the rail are fit in the
locating hole on the main unit.