15. Service Mode
15.3.13

Option Setting

A. HDD Installation
Functions
• To set when the hard disk is mounted.
Use
• Use when setting up the hard disk is mounted.
Setting/
• The default settings are "Unset."
Procedure
NOTE
• When the setting has been changed, turn off the power switch and turn it on
again more than 10 seconds after.
• If "Installed" is selected, select [User Settings] → [System Settings] → [Power-
Save Setting] → [SleepMode Setting] and set [SleepMode Setting] to "ON."
• If "Not Installed" is selected, select [User Settings] → [System Settings] →
[PowerSave Setting] → [SleepMode Setting] and set [SleepMode Setting] to
"OFF."
15.3.14

Maintenance Ctr

Functions
• To set a count value for maintenance of any given part.
Use
• When any given part is replaced.
Setting/
<Max Allowance>
Procedure
• Enter the maintenance counter value using
<Clear Counter>
• Counts up when a sheet of paper is fed through the machine.
• Select [Start] and press the Menu/Select key will clear the count.
<Count Start Date>
• Shows the date when the maintenance counter is started.
242
Set
Field Service Ver. 1.0 Oct. 2007
"Unset"
and
keys.