C3821: Fusing Abnormally Low Temperature Detection (Heating Side); C3823: Fusing Abnormally Low Temperature Detection (Pressurizing Side) - Konica Minolta bizhub C353P Service Manual

Hide thumbs Also See for bizhub C353P:
Table of Contents

Advertisement

20. Malfunction code
20.5.42
C3721: Fusing abnormally high temperature detection (heating side)
20.5.43
C3723: Fusing abnormally high temperature detection (pressurizing side)
Fusing unit
Step
Check the fusing unit for correct installation
1
(whether it is secured in position).
Check the open/close operation of the
2
upper right door.
Check the fusing unit, PRCB and DCPU for
3
proper connection and correct or change
as necessary.
4
Change fusing unit
5
Change PRCB
6
Change DCPU
20.5.44

C3821: Fusing abnormally low temperature detection (heating side)

20.5.45

C3823: Fusing abnormally low temperature detection (pressurizing side)

Fusing unit
Step
Check the fusing unit for correct installation
1
(whether it is secured in position).
Check the open/close operation of the
2
upper right door.
Check the fusing unit, PRCB and DCPU for
3
proper connection and correct or change
as necessary.
4
Change fusing unit
5
Change PRCB
6
Change DCPU
444
Relevant parts
Action
Relevant parts
Action
Field Service Ver. 1.0 Oct. 2007
DC power supply (DCPU)
Printer control board (PRCB)
WIRING DIAGRAM
Control signal
DC power supply (DCPU)
Printer control board (PRCB)
WIRING DIAGRAM
Control signal
Location (Electri-
cal component)
Location (Electri-
cal component)