Field Service Ver. 1.0 Oct. 2007
Maintenance
3.
Periodical check
3.1
Maintenance procedure (Periodical check parts)
3.1.1
Replacing the separation roller assy
A. Periodically replaced parts/cycle
• Separation roller assy: Every 300,000 prints
NOTE
• Replace the separation roller assy, feed roller and pick-up roller at the same time.
B. Replacing procedure
1. Remove the right door.
See P.13
[1]
[1]
[2]
A093F2C001DA
[2]
[1]
A093F2C500DA
3. Periodical check
2. Remove two screws [1] and remove
the jam access cover [2].
3. Remove two screws [1] and remove
the paper separation roller mounting
bracket assy [2].
3