15. Service Mode
15.8.7

Bypass Tray Adjust

Functions
• To set the maximum width and the minimum width for the manual bypass paper size
unit of the manual bypass guide.
Use
• Use when the manual bypass paper size unit of the manual bypass guide has been
changed.
• Use when a false paper size is displayed when the manual bypass is used.
1. Select [Service Mode] → [MachineAdjustment] → [BypassTray Adjust].
Setting/
Procedure
2. Select [Maximum Width].
3. Load the bypass tray with paper having a width of 297 mm.
4. Press the Menu/Select key and check that the results are [OK].
5. Select [Minimum Width].
6. Load the bypass tray with paper having a width of 100 mm.
7. Press the Menu/Select key and check that the results are [OK].
✽ Make the adjustment again if the results are [NG].
15.8.8

Exhaust Fan Delay

Functions
• To set the period of time before the exhaust fan motor stops.
Use
• At the completion of a print job/image stabilization or at jam/malfunction, the fan
motor rotating at full speed comes to a stop. The period of time before the fan motor
stops can be delayed so that ozone left around the PC drum can be discharged.
Setting/
• 0 to 15 (Min.) can be entered with the
Procedure
NOTE
• When this setting is set to 0 Min., the fan motor runs for 5 seconds before it
stops.
262
Field Service Ver. 1.0 Oct. 2007
and
keys. (Default is 0.)