10. Malfunction code
10.2.7
C11A3: Shutter drive failure
Shutter motor (M8)
Shutter home position sensor (PS14)
Step
Check the M8 connector for proper con-
1
nection and correct as necessary.
Check M8 for proper drive coupling and
2
correct as necessary.
3
M8 operation check
4
PS14 I/O check, sensor check
5
Change REYB/1
6
Change FSCB
10.2.8
C11B0: Staple unit CD drive failure
Stapling unit moving motor (M7)
Staple home position sensor (PS9)
Step
Check for interference with the shutter
1
and exit roller, and correct as necessary.
Check the M7 connector for proper con-
2
nection and correct as necessary.
Check M7 for proper drive coupling and
3
correct as necessary.
4
M7 operation check
5
PS9 I/O check, sensor check
6
Change FSCB
86
Relevant electrical parts
Relay board/1 (REYB/1)
FS control board (FSCB)
Action
Relevant electrical parts
FS control board (FSCB)
Action
Field Service Ver. 1.0 Oct. 2007
WIRING DIAGRAM
Control signal
—
—
FSCB PJ6FSCB-7 to 8
FSCB PJ18FSCB-5 (ON)
—
—
WIRING DIAGRAM
Control signal
—
—
—
FSCB PJ10FSCB-1 to 4
FSCB PJ13FSCB-5 (ON)
—
Location
(Electrical
component)
—
—
FS-519 J-5
FS-519 J-5
—
—
Location
(Electrical
component)
—
—
—
FS-519 C-3 to 4
FS-519 C-4 to 5
—