22. Image quality problem
22.1.2

Level history 1

TCR-C
TCR-M
TCR-Y
TCR-K
IDC1
IDC2
Temp-Heat
Temp-Press
462
• Shows the T/C ratio reading taken last (in 0.01 % increments).
• Standard value: 6 to 8 %
• Relevant components: TCR sensor
• "Reading taken last" means:
Latest value
When the Start key is pressed, the output value is displayed while a test
print is being produced.
• Shows the IDC bare surface output reading taken last (in 0.01 V incre-
ments).
• It should normally be around 4.3 V.
• The output range is 0 V to 5 V.
• "Reading taken last" means: Present value
• Relevant components: IDC sensor, transfer belt unit
• Shows the temperature of the each part of the fusing unit
(in 1 °C increments).
• Relevant components: Fusing unit
Field Service Ver. 1.0 Oct. 2007