Field Service Ver. 8.0 Jun. 2008
Maintenance
3.
Periodical check
3.1
Maintenance items
NOTE
• Cleaning/replacement cycle for each maintenance item of main body/options can
be evaluated with each life counter value of [Service mode] → [Counter] → [Life].
3.1.1
Main body
A. Parts to be replaced by users (CRU)
No
Class
1
Imaging unit Y/M/C
Electrostatic charger wire
2
Y/M/C
Processing
3
sections
PH window Y/M/C/K
4
Toner cartridge Y/M/C
5
Toner cartridge K
Image transfer
6
Waste toner box
section
*1: The parts can be replaced either by user or service engineer.
For details of setting, see [Unit Change] on "Adjustment/Setting."
See P.496
*2: A waste toner full condition is detected with detecting the actual waste toner emissions.
B. Maintenance call (per 100,000-print)
No.
Class
Paper feed and image con-
1
ditions
Overall
2
Appearance
3
Timing roller
Conveyance
section
4
Paper dust remover
Image transfer
5
Around waste toner port
section
6
Duplex section Duplex transport roller
C. Periodical parts replacement/cleaning 1 (per 150,000-print)
No.
Class
Paper feed and image
1
conditions
Overall
2
Appearance
Processing
3
Color toner filter
section
Parts to be replaced
Parts to be replaced
Parts to be replaced
Cycle
Clean Replace
100,000
When TC (Y,M,C) is
replaced
When TC is replaced
27,000
45,000
(57,000)
Qt.
Check Clean Replace
⎯
●
⎯
●
●
⎯
●
⎯
●
⎯
●
⎯
●
Qt.
Check Clean Replace
⎯
●
⎯
●
●
●
1
3. Periodical check
Descrip-
tions
●
*1
●
●
●
*1
●
*1
●
*1,2
Lubri-
Descrip-
cation
tions
Lubri-
Descrip-
cation
tions
15