Switchport Trunk Allowed Vlan - Supermicro SSE-G48-TG4 Reference Manual

Intelligent switch
Hide thumbs Also See for SSE-G48-TG4:
Table of Contents

Advertisement

Super Micro Intelligent Switch Command Line Interface User Guide
15.18

switchport trunk allowed vlan

This command configures the allowed vlans for trunk ports. By default, all the VLANs configured
on a switch are allowed on the trunk interfaces. User can limit the allowed vlans on the trunk ports
using this command.
switchport trunk allowed vlan { <vlan-list> | add <vlan-list> | all |
none | except <vlan-list> | remove <vlan-list> }
Syntax
<vlan-list> - This can be any VLAN number or list of VLAN numbers. Multiple VLAN
numbers can be provided as comma-separated values. Consecutive VLAN numbers can be
provided as a range, such as 5-10.
add – Adds the given vlans to the allowed vlans list
all – Configures all the vlans on the switches as the allowed vlans on this port
none – Removes the all the allowed vlans configured on this port
except – Configures all the vlans of the switch except the given vlans as the allowed vlan on this
port
remove – Removes the given vlans from the allowed vlans list configured on this port
Mode
Interface Configuration Mode
Defaults
All vlans
Example
SMIS(config-if)# switchport trunk allowed vlan 3-10
Related Command
show vlan port config - Displays the VLAN related parameters specific for ports
Release : 1.1f
356 / 985

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents