15.19

switchport acceptable-frame-type

This command configures the acceptable frame type for the port. The no form of this command
sets the default value of acceptable frame type - "all" where all frames will be accepted.
switchport acceptable-frame-type {all | tagged |
untaggedAndPrioritytagged }
no switchport acceptable-frame-type
Syntax Description
all - All frames
tagged - Tagged frames
untaggedAndPrioritytagged - Untagged and priority tagged frames
Mode
Interface Configuration Mode
Defaults
all
Example
SMIS(config-if)# switchport acceptable-frame-type tagged
When set to "tagged" the device will discard untagged and priority tagged frames
received on the port and will process only the VLAN tagged frames.
When set to "all" untagged frames or priority-tagged frames received on the port are also
accepted.
When set to "untaggedAndPrioritytagged", untagged and priority tagged frames alone are
accepted and tagged frames are dropped.
Related Command
show vlan port config - Displays the VLAN related parameters specific for ports
Release : 1.1f