Layer 3 Vlan Interface - Supermicro SSE-G24-TG4 Configuration Manual

L2 / l3 switches
Hide thumbs Also See for SSE-G24-TG4:
Table of Contents

Advertisement

Step 5
end
Step 6
showip interface
1.2.7
IP Routing is enabled by default in Supermicro switches.
The "switchport" command deletes the Physical Layer 3 interface and the interface is reset
as a Layer2 interface.
The example below shows the commands used to configure a Physical Layer3 Interface.
SMIS# configure terminal
SMIS(config)# interface Gi 0/22
SMIS(config-if)# no switchport
SMIS(config-if)# ip address 20.20.20.1 255.255.255.0
SMIS(config-if)# end
SMIS# show ip interface
Gi0/22 is up, line protocol is up
Internet address is 20.20.20.1/24
Broadcast address is20.20.20.255
mgmt is up, line protocol is down
Internet address is 192.168.100.102/24
Broadcast address is192.168.100.255
Gateway 0.0.0.0

1.2.8 Layer 3 VLAN Interface

VLANs typically operate at Layer 2. When aLayer2 VLAN is configured with an IP address, it behaves as a
logical Layer 3 VLAN interface. A L3 VLAN interface provides logical routing interfaces to VLANs on Layer
address with a prefix length of value 1-
32.
subnet-mask – A valid IP subnet mask.
1.2.6
Secondary
addresses to network interfaces.
Exits the configuration mode.
Displays
information.
Supermicro L2/L3 Switches Configuration Guide
-
Assigns
multiple
the
Layer
3
interface
7
IP

Advertisement

Table of Contents
loading

Table of Contents