Flowcontrol - Supermicro SSE-G48-TG4 Reference Manual

Intelligent switch
Hide thumbs Also See for SSE-G48-TG4:
Table of Contents

Advertisement

Super Micro Intelligent Switch Command Line Interface User Guide

3.63 flowcontrol

This command is used to set the send or receive flow-control value for an interface. If flow control
send is on for a device, and if it detects any congestion at its end, then it will notify the link partner
or the remote device of the congestion by sending a pause frame.
If flowcontrol receive is on for the remote device and it receives a pause frame, then it stops
sending any data packets. This prevents any loss of data packets during the congestion period.
You can use both the receive off and send off keywords to disable flow control.
flowcontrol { send | receive} { on | off }
Syntax Description
send - Interface to send flow control packets to a remote device
receive - Interface to receive flow control packets from a remote device
on - If used with receive allows an interface to operate with the attached device to send flow
control packets. If used with send the interface sends flowcontrol packets
to a remote device if the device supports it
off - Turns-off the attached devices' (when used with receive) or the local ports' (when used
with send) ability to send flow-control packets to an interface or to a remote device respectively
Mode
Interface Configuration Mode
Defaults
The default flow control for the interfaces are flowcontrol receive off, flowcontrol send off
Example
SMIS(config-if)# flowcontrol send on
Related Commands
show interfaces - Displays the interface status and configuration
show flow-control - Displays the flowcontrol information
Release : 1.1f