Table 41 Analog Terminal Adapter - Advanced Settings Parameters (continued)
Field
Flash-hook Maximum
(msec)
Supervisory Disconnect
Pulse (msec)
Purpose
Set this value to define the maximum time the hook
switch can be depressed for the NBX system to
recognize the event as a valid flash hook signal. If the
hook switched is depressed longer than this time, the
NBX system treats the event as if you had hung up the
telephone.
Default: Depends on the country in which the NBX
system is operating.
When you load a regional pack (Operations >
Regional Software) and select the tones and cadences
appropriate for your location (System Configuration >
System Settings > Regional Settings > Advanced), the
default value is set on your NBX system.
Minimum: 0 msec
Maximum: 2000 msec
Set this value to define the duration of the supervisory
disconnect pulse (battery denial) that disconnects the
current call.
Default: Depends on the country in which the NBX
system is operating.
When you load a regional pack (Operations >
Regional Software) and select the tones and cadences
appropriate for your location (System Configuration >
System Settings > Regional Settings > Advanced), the
default value is set on your NBX system.
Minimum: 0 (this setting disables the function)
Maximum: 2000 msec