Advanced Settings - 3Com SuperStack 3 NBX Administrator's Manual

Hide thumbs Also See for SuperStack 3 NBX:
Table of Contents

Advertisement

232
C
3: D
HAPTER
EVICE

Advanced Settings

C
ONFIGURATION
Table 40 Device Status Fields (continued)
Field
Dialog Refresh
Device Refresh
Reset Device
Time Last Seen
Error Count
Error Code
Performance Data
Debug Data
Actor Data
6 To optionally send a status message to the Call Processor about the ATA
or port, select Device Refresh and click Apply.
7 To optionally reset the ATA or port, select Reset Device and click Apply. A
dialog box prompts you to confirm the reset.
8 Click Yes. The ATA or port resets itself.
CAUTION: On the 3C10114 Analog Terminal Card, you can reboot
individual ports without affecting the other ports. However, if you reboot
a port on the 3C10114C Analog Terminal Card, all four ports on the card
are rebooted. Active calls on any of these ports are disrupted.
9 Click OK.
You can set the audio gain and timing controls on each port of an Analog
Terminal Card, or on a single-port Analog Terminal Adapter. To set these
parameters:
1 In the NBX NetSet - Main Menu window, click Device Configuration.
2 Click the ATA tab.
Purpose
How often to renew Status information. You can select
either Manual, for manual refresh, or an interval of from
5–60 seconds, at 5–second intervals.
Forces the ATA or ATC port to send a status message to
the Call Processor immediately.
Reboots the ATA or ATC port. The ATA or ATC port
renews communications with the Call Processor and
receives a new download of its operating software.
The time when the ATA or ATC port last communicated
to the Call Processor.
Advanced diagnostic data for use by technical support
personnel.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nbx 100 900-0093-01Nbx 100

Table of Contents