Using Another Company's Master Unit
Model
Basic Unit
Expan-
sion Unit
DRT2-ID32BV(-1)
DRT2-OD32BV(-1)
DRT2-MD32BV(-1)
DRT2-ID32SL(-1)
DRT2-OD32SL(-1)
DRT2-MD32SL(-1)
DRT2-ID32SLH(-1)
DRT2-OD32SLH(-1)
DRT2-MD32SLH(-1)
Name
Produced
connection
size
Input Data
0004 (hexa-
decimal)
Generic Sta-
0001 (hexa-
tus
decimal)
Input Data +
0005 (hexa-
Generic Sta-
decimal)
tus
Output Data
---
Generic Sta-
0001 (hexa-
tus
decimal)
Input Data
0002 (hexa-
decimal)
Generic Sta-
0001 (hexa-
tus
decimal)
Input Data +
0003 (hexa-
Generic Sta-
decimal)
tus
Output Data
---
Input Data
0004 (hexa-
decimal)
Generic Sta-
0001 (hexa-
tus
decimal)
Input Data +
0005 (hexa-
Generic Sta-
decimal)
tus
Output Data
---
Generic Sta-
0001 (hexa-
tus
decimal)
Input Data
0002 (hexa-
decimal)
Generic Sta-
0001 (hexa-
tus
decimal)
Input Data +
0003 (hexa-
Generic Sta-
decimal)
tus
Output Data
---
Input Data
0004 (hexa-
decimal)
Generic Sta-
0001 (hexa-
tus
decimal)
Input Data +
0005 (hexa-
Generic Sta-
decimal)
tus
Output Data
---
Generic Sta-
0001 (hexa-
tus
decimal)
Input Data
0002 (hexa-
decimal)
Generic Sta-
0001 (hexa-
tus
decimal)
Input Data +
0003 (hexa-
Generic Sta-
decimal)
tus
Output Data
---
Produced
Produced
connection
connection
path length
path
0006
20_04_24_06
_30_03
0006
20_04_24_64
_30_03
0006
20_04_24_68
_30_03
0000
---
0006
20_04_24_64
_30_03
0006
20_04_24_05
_30_03
0006
20_04_24_64
_30_03
0006
20_04_24_66
_30_03
0000
---
0006
20_04_24_06
_30_03
0006
20_04_24_64
_30_03
0006
20_04_24_68
_30_03
0000
---
0006
20_04_24_64
_30_03
0006
20_04_24_05
_30_03
0006
20_04_24_64
_30_03
0006
20_04_24_66
_30_03
0000
---
0006
20_04_24_06
_30_03
0006
20_04_24_64
_30_03
0006
20_04_24_68
_30_03
0000
---
0006
20_04_24_64
_30_03
0006
20_04_24_05
_30_03
0006
20_04_24_64
_30_03
0006
20_04_24_66
_30_03
0000
---
Appendix B
Consumed
Consumed
connection
connection
path length
path
0000
---
0000
---
0000
---
0000
---
0000
---
0000
---
0000
---
0000
---
0000
---
0000
---
0000
---
0000
---
0000
---
0000
---
0000
---
0000
---
0000
---
0000
---
0000
---
0000
---
0000
---
0000
---
0000
---
0000
---
0000
---
0000
---
0000
---
527
527

Hide quick links: