Temperature Input Terminals
Convertible
Temperature Ranges
DRT2-TS04T
DRT2-TS04T
Note The temperature ranges listed above are the ranges in which the input accu-
racy is within the specified range.
The convertible data range depends on the selected sensor, as shown in the
following tables.
Input type
−20 to 1,720
R
−20 to 1,720
S
−220 to 1,320
K1
−20.0 to 520.0
K2
−120 to 870
J1
−20.0 to 420.0
J2
−220.0 to 420.0
T
−20 to 620
E
−120 to 870
L1
−20.0 to 420.0
L2
−220.0 to 420.0
U
−220 to 1,320
N
−20 to 2,320
W
B
80 to 1,820
−20 to 1,320
PL2
Note
1. The display data will be clamped at the minimum value when the value is
below the minimum display value but higher than the value at which an
off-wire condition is detected.
2. When an off-wire condition is detected, the display data will be 7FFF. (In
1/100 display mode, the display data will be 7FFF FFFF.)
Input type
−220.0 to 870.0
PT
−220.0 to 670.0
JPT
−220.0 to 220.0
PT2
−220.0 to 220.0
JPT2
Note
1. If the Unit is subjected to sudden temperature changes, moisture may con-
dense in the Unit and cause incorrect indications. If there is condensation,
remove the Unit from service and keep it at a steady temperature for about
1 hour before using it again.
2. If the input temperature exceeds the convertible range, the temperature
data will be clamped at the minimum or maximum value.
If the temperature exceeds the convertible range by a certain value, an
off-wire condition (broken or disconnected input wire) will be detected and
the temperature data will be set to 7FFF. If the input temperature returns
to the convertible range, the off-wire detection function will be reset auto-
matically and normal conversion data will be stored.
°C
Display
FFEC to 06B8
FFEC to 06B8
FF24 to 0528
FF38 to 1450
FF88 to 0366
FF38 to 1068
F768 to 1068
FFEC to 026C
FF88 to 0366
FF38 to 1068
F768 to 1068
FF24 to 0528
FFEC to 0910
0050 to 071C
FFEC to 0528
°C
Display
F768 to 21FC
F768 to 1A2C
F768 to 0898
F768 to 0898
Section 7-6
°F
Display
−20 o 3,020
FFEC to 0BCC
−20 to 3,020
FFEC to 0BCC
−320 to 2,320
FEC0 to 0910
−20.0 to 920.0
FF38 to 23F0
−120 to 1,520
FF88 to 05F0
−20.0 to 770.0
FF38 to 1E14
−320.0 to 720.0
F380 to 1C20
−20 to 1,120
FFEC to 0460
−120 to 1,520
FF88 to 05F0
−20.0 to 770.0
FF38 to 1E14
−320.0 to 720.0
F380 to 1C20
−320 to 2,320
FEC0 to 0910
−20 to 4,120
FFEC to 1018
280 to 3,220
0118 to 0C94
−20 to 2,320
FFEC to 0910
°F
Display
−320.0 to
F380 to 3B60
1,520.0
−320.0 to
F380 to 2FA8
1,220.0
−320.0 to 400.0
F380 o 0FA0
−320.0 to 400.0
F380 to 0FA0
383