Omron DRT2 SERIES DEVICENET SLAVES - OPERATION MANUAL 04-2008 Operation Manual page 315

Devicenet slaves
Hide thumbs Also See for DRT2 SERIES DEVICENET SLAVES - OPERATION MANUAL 04-2008:
Table of Contents

Advertisement

Overview of Analog Slaves
Slave
Model
Input range switching
Node address setting
Baud rate setting
Communications error output
Scaling, user adjustment
(maintenance function), cumu-
lative counter (maintenance
function), last maintenance
date (maintenance function)
Temperature Input Terminals
Slave
Model
Input type
Dimensions
Maintenance method
Input type setting method
Input type setting
Input type (sensor type)
Input accuracy
Conversion cycle
1/100 display mode
DRT1-compatible 1/100 dis-
play mode
294
DRT1 Series
DRT1-DA02
Set using the rotary switches.
Set using the DIP switch.
Set using the DIP switch.
Set using the DIP switch.
Not supported.
DRT1 Series
DRT1-TS04T
DRT1-TS04P
Thermocouple
Platinum resistance
thermometer
150 × 40 × 50 (W × H × D)
Replacement of each Unit
Set with a Rotary Switch.
All 4 inputs are set together.
R, S, K1, K2, J1, J2,
PT, JPT
T, B, L1, L2, E, U, N,
W, PL2
±
±
0.5% of indication
0.5% of indication
±
value or
2°C,
value or
whichever is larger)
whichever is larger)
±
±
1 digit max.
1 digit max.
250 ms/ 4 points
The temperature data is multiplied by 100
and sent to the Master as 6-digit hexadeci-
mal data. In this case, the hexadecimal data
is divided into two parts and the parts are
sent alternately each 125 ms. (The data is
sent in 1-word units).
---
DRT2-DA02
Set using the DIP switch or the Configura-
tor.
Set using the rotary switches or the Config-
urator.
Automatically detected: Uses the baud rate
set for the Master Unit.
Set using the Configurator.
Supported. (Set using the Configurator.)
DRT2-TS04T
Thermocouple
115 × 49.7 × 50 (W × H × D)
Just the Terminal Block can be removed.
Set with a DIP switch (hardware) setting or
Configurator (software) setting.
Inputs can be set individually.
(All inputs are set to the same input type if
the DIP switch (hardware) setting is used. In
addition, the following settings cannot be
set individually: Off-wire (disconnection)
display setting, Number of display digits set-
ting, and °C/°F setting.)
R, S, K1, K2, J1, J2,
T, B, L1, L2, E, U, N,
W, PL2
±
0.3% of indication
±
±
1°C,
value or
1°C,
whichever is larger)
±
1 digit max.
(See note.)
The temperature data is multiplied by 100
and sent to the Master as 8-digit hexadeci-
mal data. (The data is sent in 2-word units).
The temperature data is multiplied by 100
and sent to the Master as 6-digit hexadeci-
mal data. In this case, the hexadecimal data
is divided into two parts and the parts are
sent alternately each 125 ms. (The data is
sent in 1-word units).
Section 7-1
DRT2 Series
DRT2 Series
DRT2-TS04P
Platinum resistance
thermometer
PT, JPT, PT2, JPT2
−200 to 850°C input
range:
±
0.3% of indication
±
value or
0.8°C,
whichever is larger)
±
1 digit max.
−200 to 200°C input
range:
±
0.3% of indication
±
value or
0.5°C,
whichever is larger)
±
1 digit max.