Temperature Input Terminals
Item
Terminal strength
Weight
Performance Specifications
Item
Model
Input type
Indicator accuracy
Conversion cycle
Temperature conversion
data
Isolation method
Effects of Mounting
Direction on Indicator
Accuracy
378
Pulling: 50 N
160 g max.
DRT2-TS04T
Switchable between R, S, K1, K2, J1, J2, T, B,
L1, L2, E, U, N, W, and PL2
When set with Configurator: Input types can
be set individually for each input.
Wen set with DIP switch: The same input type
setting applies to all 4 inputs.
±
(
0.3% of indication value or
±
is larger)
1 digit max.
(See note 2.)
Indicator Accuracy in Exceptional Cases
Input type and
temperature range
K1, K2, T, and N below
±2°C ±1 digit max.
− 100 ° C
U, L1, and L2
±2°C ±1 digit max.
R and S below 200 ° C
±3°C ±1 digit max.
B below 400 ° C
Not specified.
W
±0.3% of indication value or
±3°C (whichever is larger) ±1
digit max.
PL2
±0.3% of indication value or
±2°C (whichever is larger) ±1
digit max.
250 ms/4 points
Hexadecimal data (4-digit hexadecimal when normal display mode is selected or 8-digit hexa-
decimal when 1/100 display mode is selected.)
Between input and communication lines: Photocoupler isolation
Between temperature input signals: Photocoupler isolation
Note
1. A current of 0.35 mA flows to sensors connected to the DRT2-TS04P.
2. The indicator accuracy specifications differ depending on the mounting di-
rection. Refer to the above table for details.
In the DRT2-TS04T, a cold junction compensator is included in the Terminal
Block. The indicator accuracy will be reduced depending on the mounting
direction if just the Terminal Unit itself is replaced and the serial numbers of
the Terminal Block and Terminal Unit do not match. The serial numbers of the
Terminal Block and Terminal Unit can be found on the labels affixed to the
Units as shown below.
Terminal Unit Label
Remove the terminal block. The label is attached
to the Unit under the terminal block.
Specifications
160 g max.
Specifications
DRT2-TS04P (See note 1.)
Switchable between PT, JPT, PT2, and JPT2
When set with Configurator: Input types can
be set individually for each input.
Wen set with DIP switch: The same input type
setting applies to all 4 inputs.
−200 to 850°C input range:
±
1°C, whichever
±
(
0.3% of indication value or
ever is larger)
−200 to 200°C input range:
±
(
0.3% of indication value or
Input accuracy
ever is larger)
Section 7-6
±
0.8°C, which-
±
1 digit max.
±
0.5°C, which-
±
1 digit max.
Terminal Block Label
The label is attached to the
back of the terminal block.