Analog Output Terminals
Setting Using the DeviceNet Configurator
1,2,3...
370
1. Double-click the icon of the Analog Slave to be set in the Main Window and
open the Edit Device Parameters Window. (From the Maintenance Mode
Window, click the right mouse button over the Slave icon and select Pa-
rameters and Edit.)
2. Select the Tab Page for the output where scaling is to be performed, and
select Scaling under the Function Choice heading.
3. To select the scaling type, click the Scaling Tab, and select either Default
Scaling or User Scaling. The following example shows when User Scal-
ing is selected.
Section 7-5